Calculeter guide

PFT Calculator

SPIROMETRY • LUNG VOLUMES • RESPONSE

PFT Calculator

Calculate pulmonary function test percentages, FEV₁/FVC ratio, ventilatory pattern and bronchodilator response from a laboratory report.

✓ Uses report-specific LLN values
Educational interpretation only.This tool does not diagnose lung disease. Seek urgent medical care for severe or rapidly worsening breathing difficulty, blue or grey lips, chest pain, confusion or fainting.
01

Enter values from the PFT report

Pre-bronchodilator spirometry

Enter measured and predicted values in litres.

Lower limits of normal

Copy these reference limits from the same report. They are optional, but a physiologic pattern cannot be classified reliably without them.

Post-bronchodilator values optional

Enter either or both post-bronchodilator measurements. Response is change ÷ predicted × 100.

Total lung capacity (TLC) optional

Enter all three TLC values together to assess restriction.

Diffusing capacity (DLCO) optional

Use the same DLCO unit for all three entries. The calculator compares the numbers without converting units.

Your report values stay in the browser and are not submitted or stored.

REPORT-BASED CALCULATION

How this PFT calculator works

This calculator does not create predicted values from age, height or demographic information. Instead, it uses the measured, predicted and lower-limit values produced by the pulmonary function laboratory’s chosen reference equations.

FEV₁ percent predicted

Measured FEV₁ ÷ predicted FEV₁ × 100

FVC percent predicted

Measured FVC ÷ predicted FVC × 100

FEV₁/FVC ratio

Measured FEV₁ ÷ measured FVC × 100

Bronchodilator change

(Post − pre) ÷ predicted × 100

Current ERS/ATS interpretation uses lower limits of normal, commonly the 5th percentile of an appropriate reference distribution. It does not recommend treating a fixed FEV₁/FVC ratio of 0.70 or 80% predicted as a universal definition of normal.

How ventilatory patterns are classified

Entered resultEducational physiologic patternImportant limitation
FEV₁/FVC below LLN; TLC not lowObstructive ventilatory impairmentDoes not identify the cause
TLC below LLN; ratio not lowRestrictive ventilatory impairmentTLC method and test quality matter
Ratio and TLC both below LLNMixed obstructive and restrictive impairmentRequires complete lung-volume assessment
Normal ratio with FVC below LLN, no TLCPossible restrictionA low FVC alone does not prove restriction
DLCO below LLNReduced gas transferInterpret with haemoglobin correction and other DLCO measures

The calculator describes physiology only. Asthma, COPD, interstitial lung disease and other clinical diagnoses require professional assessment beyond a numeric pattern.

Bronchodilator response calculation

Current thresholdA response is positive when either FEV₁ or FVC increases by more than 10% of that variable’s predicted value.

For example, if FEV₁ rises from 2.0 L to 2.4 L and predicted FEV₁ is 3.2 L, the response is (2.4 − 2.0) ÷ 3.2 × 100 = 12.5%. The calculator also shows the change in millilitres and percentage of baseline for context.

A positive or negative bronchodilator response does not by itself confirm or exclude a specific diagnosis.

What common pulmonary function values mean

FEV₁

One-second forced volume

Air exhaled during the first second of a forced expiration.

FVC

Forced vital capacity

Total air exhaled during the forced spirometry manoeuvre.

FEV₁/FVC

Expiratory ratio

Used with its LLN to identify airflow obstruction.

TLC

Total lung capacity

Total air in the lungs after maximal inspiration; low TLC confirms restriction physiologically.

DLCO

Diffusing capacity

Estimates transfer of carbon monoxide from alveoli to blood and requires clinical context.

Worked PFT calculator example

Pre FEV₁ / predicted1.80 L / 3.00 L = 60%
Pre FVC / predicted3.00 L / 3.80 L = 78.9%
FEV₁/FVC1.80 ÷ 3.00 = 60%
Ratio LLN70%
Post FEV₁2.20 L
FEV₁ response(2.20 − 1.80) ÷ 3.00 = 13.3%
Educational resultObstructive pattern; positive bronchodilator response by FEV₁

This example demonstrates the arithmetic only. A clinician must review test acceptability, flow-volume curves, symptoms and the complete report.

Safety and interpretation limits

Pulmonary function tests help describe how the lungs move air and exchange gas, but calculations are only one part of interpretation. Do not change inhalers, oxygen or other treatment based on this page. Review the complete report with the ordering clinician or a respiratory specialist.

Professional references: American Thoracic Society implementation tools and the ERS/ATS interpretive technical standard.

PFT calculator FAQs

What does this PFT calculator calculate?

It calculates FEV1 and FVC percent predicted, the FEV1/FVC ratio, optional TLC and DLCO percent predicted, and pre-to-post bronchodilator changes. When lower limits of normal are entered, it provides an educational physiologic pattern.

What is FEV1?

FEV1 is the forced expiratory volume exhaled during the first second of a forced breath. It is reported in litres and compared with a reference value appropriate for the person and laboratory.

What is FVC?

FVC is forced vital capacity, the total volume forcefully exhaled after a full inhalation during the spirometry manoeuvre.

How is the FEV1/FVC ratio calculated?

Divide measured FEV1 by measured FVC and multiply by 100. Current ATS/ERS guidance compares the result with the report’s lower limit of normal rather than relying on a universal fixed ratio.

Does a low FVC prove restriction?

No. A low FVC with a normal ratio can suggest possible restriction, but restriction is confirmed physiologically by a total lung capacity below its lower limit of normal.

What indicates an obstructive ventilatory impairment?

The current interpretive standard defines airflow obstruction when the FEV1/FVC ratio is below the lower limit of normal for the reference equation used by the laboratory.

What is a significant bronchodilator response?

The 2021/2022 ERS/ATS strategy defines a positive response as an increase in FEV1 or FVC greater than 10% of that variable’s predicted value.

Why does this calculator not predict normal lung function from age and height?

Reference equations and their appropriate inputs vary. The calculator uses the predicted and lower-limit values already produced by the testing laboratory so it does not silently select an unsuitable reference equation.

Can this calculator diagnose asthma, COPD or pulmonary fibrosis?

No. PFT patterns classify physiology and must be combined with symptoms, test quality, medical history, examination and other investigations by a qualified clinician.

Does the calculator store PFT values?

No. All calculations run locally in the browser. The entered laboratory values are not submitted or saved by this plugin.