REPORT-BASED CALCULATION
How this PFT calculator works
This calculator does not create predicted values from age, height or demographic information. Instead, it uses the measured, predicted and lower-limit values produced by the pulmonary function laboratory’s chosen reference equations.
FEV₁ percent predicted
Measured FEV₁ ÷ predicted FEV₁ × 100FVC percent predicted
Measured FVC ÷ predicted FVC × 100FEV₁/FVC ratio
Measured FEV₁ ÷ measured FVC × 100Bronchodilator change
(Post − pre) ÷ predicted × 100Current ERS/ATS interpretation uses lower limits of normal, commonly the 5th percentile of an appropriate reference distribution. It does not recommend treating a fixed FEV₁/FVC ratio of 0.70 or 80% predicted as a universal definition of normal.
How ventilatory patterns are classified
| Entered result | Educational physiologic pattern | Important limitation |
|---|---|---|
| FEV₁/FVC below LLN; TLC not low | Obstructive ventilatory impairment | Does not identify the cause |
| TLC below LLN; ratio not low | Restrictive ventilatory impairment | TLC method and test quality matter |
| Ratio and TLC both below LLN | Mixed obstructive and restrictive impairment | Requires complete lung-volume assessment |
| Normal ratio with FVC below LLN, no TLC | Possible restriction | A low FVC alone does not prove restriction |
| DLCO below LLN | Reduced gas transfer | Interpret with haemoglobin correction and other DLCO measures |
The calculator describes physiology only. Asthma, COPD, interstitial lung disease and other clinical diagnoses require professional assessment beyond a numeric pattern.
Bronchodilator response calculation
For example, if FEV₁ rises from 2.0 L to 2.4 L and predicted FEV₁ is 3.2 L, the response is (2.4 − 2.0) ÷ 3.2 × 100 = 12.5%. The calculator also shows the change in millilitres and percentage of baseline for context.
A positive or negative bronchodilator response does not by itself confirm or exclude a specific diagnosis.
What common pulmonary function values mean
One-second forced volume
Air exhaled during the first second of a forced expiration.
Forced vital capacity
Total air exhaled during the forced spirometry manoeuvre.
Expiratory ratio
Used with its LLN to identify airflow obstruction.
Total lung capacity
Total air in the lungs after maximal inspiration; low TLC confirms restriction physiologically.
Diffusing capacity
Estimates transfer of carbon monoxide from alveoli to blood and requires clinical context.
Worked PFT calculator example
This example demonstrates the arithmetic only. A clinician must review test acceptability, flow-volume curves, symptoms and the complete report.
Safety and interpretation limits
Pulmonary function tests help describe how the lungs move air and exchange gas, but calculations are only one part of interpretation. Do not change inhalers, oxygen or other treatment based on this page. Review the complete report with the ordering clinician or a respiratory specialist.
Professional references: American Thoracic Society implementation tools and the ERS/ATS interpretive technical standard.
PFT calculator FAQs
What does this PFT calculator calculate?
It calculates FEV1 and FVC percent predicted, the FEV1/FVC ratio, optional TLC and DLCO percent predicted, and pre-to-post bronchodilator changes. When lower limits of normal are entered, it provides an educational physiologic pattern.
What is FEV1?
FEV1 is the forced expiratory volume exhaled during the first second of a forced breath. It is reported in litres and compared with a reference value appropriate for the person and laboratory.
What is FVC?
FVC is forced vital capacity, the total volume forcefully exhaled after a full inhalation during the spirometry manoeuvre.
How is the FEV1/FVC ratio calculated?
Divide measured FEV1 by measured FVC and multiply by 100. Current ATS/ERS guidance compares the result with the report’s lower limit of normal rather than relying on a universal fixed ratio.
Does a low FVC prove restriction?
No. A low FVC with a normal ratio can suggest possible restriction, but restriction is confirmed physiologically by a total lung capacity below its lower limit of normal.
What indicates an obstructive ventilatory impairment?
The current interpretive standard defines airflow obstruction when the FEV1/FVC ratio is below the lower limit of normal for the reference equation used by the laboratory.
What is a significant bronchodilator response?
The 2021/2022 ERS/ATS strategy defines a positive response as an increase in FEV1 or FVC greater than 10% of that variable’s predicted value.
Why does this calculator not predict normal lung function from age and height?
Reference equations and their appropriate inputs vary. The calculator uses the predicted and lower-limit values already produced by the testing laboratory so it does not silently select an unsuitable reference equation.
Can this calculator diagnose asthma, COPD or pulmonary fibrosis?
No. PFT patterns classify physiology and must be combined with symptoms, test quality, medical history, examination and other investigations by a qualified clinician.
Does the calculator store PFT values?
No. All calculations run locally in the browser. The entered laboratory values are not submitted or saved by this plugin.